347132938
|
0112300
|
2023-11-30
|
806 BRONCOS HIGHWAY, MAPLEVILLE, RI, 02839
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-11-30
|
Emphasis |
L: FORKLIFT, N: AMPUTATE
|
Case Closed |
2024-03-04
|
Related Activity
Type |
Inspection |
Activity Nr |
1656952 |
Safety |
Yes |
|
|
346569528
|
0112300
|
2023-03-16
|
806 BRONCOS HIGHWAY, MAPLEVILLE, RI, 02839
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-03-16
|
Emphasis |
N: AMPUTATE
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C01 |
Issuance Date |
2023-05-31 |
Abatement Due Date |
2023-07-18 |
Current Penalty |
4175.0 |
Initial Penalty |
4175.0 |
Final Order |
2023-06-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Inspection NR |
1713293 |
FTA Issuance Date |
2024-02-28 |
FTA Current Penalty |
5000.0 |
FTA Final Order Date |
2024-03-28 |
Citation text line |
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. (a) Worksite: On or about 03-16-2023, the employer did not establish a lockout/tagout program consisting of energy control procedures, employee training and periodic inspections. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19100178 L04 III |
Issuance Date |
2023-05-31 |
Abatement Due Date |
2023-07-18 |
Current Penalty |
1670.0 |
Initial Penalty |
1670.0 |
Final Order |
2023-06-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Inspection NR |
1713293 |
FTA Issuance Date |
2024-02-28 |
FTA Current Penalty |
3740.0 |
FTA Final Order Date |
2024-03-28 |
Citation text line |
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years. (a) Worksite: On or about 3/16/2023, the employer did not ensure that each forklift operator received a forklift skills evaluation once every three years. Sandberg Enterprises, Inc. was previously cited for a violation of this occupational health and safety standard, 29 CFR 1910.178(l)(4)(iii), which is contained in OSHA inspection number 1302727, citation number 2, item 2b and was affirmed on a final order on 4/10/2018, with respect to the workplace located at 806 Broncos Highway, Mapleville, RI 02839. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19040033 A |
Issuance Date |
2023-05-31 |
Abatement Due Date |
2023-07-18 |
Current Penalty |
835.0 |
Initial Penalty |
835.0 |
Final Order |
2023-06-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.33(a): At this establishment, the employer did not retain (save) the OSHA 300 Log, the privacy case list (if one exists), the annual summary, and the OSHA 301 Incident Report forms for five (5) years following the end of the calendar year that these records covered. (a) Worksite: On or about 3/16/2023, the employer did not retain the OSHA 300 logs, the annual summary, and the OSHA 301's for the past 5 years. |
|
Citation ID |
04001A |
Citaton Type |
Other |
Standard Cited |
19030019 C01 |
Issuance Date |
2023-10-05 |
Abatement Due Date |
2023-11-09 |
Current Penalty |
469.0 |
Initial Penalty |
469.0 |
Final Order |
2023-11-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1903.19(c)(1):The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: (a) Establishment: As of October 5, 2023, the employer had not certified to OSHA that the abatement had been completed for Citation 1, Item 1, Citation 2, Item 1, and Citation 3, Item 1 from inspection number 1656952, issued on 5/31/2023, with a final order date of 6/29/2023. |
|
Citation ID |
04001B |
Citaton Type |
Other |
Standard Cited |
19030019 D01 |
Issuance Date |
2023-10-05 |
Abatement Due Date |
2023-11-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-11-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1903.19(d)(1):The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. (a) Establishment: As of October 5, 2023, the employer had not provided the required abatement documentation to OSHA for Citation 1, Item 1, Citation 2, Item1, and Citation 3, Item 1 from inspection number 1656952, issued on 5/31/2023, with a final order date of 6/29/2023. |
|
|
343027272
|
0112300
|
2018-03-20
|
806 BRONCOS HIGHWAY, MAPLEVILLE, RI, 02839
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-03-20
|
Emphasis |
L: FORKLIFT, P: AMPUTATE, N: AMPUTATE
|
Case Closed |
2020-01-09
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Other |
Standard Cited |
19100179 J01 II B |
Issuance Date |
2018-03-23 |
Abatement Due Date |
2018-05-22 |
Current Penalty |
0.0 |
Initial Penalty |
2513.0 |
Final Order |
2018-04-10 |
Nr Instances |
5 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.179(j)(1)(ii)(b): Complete inspections of the crane shall be performed at intervals of 1 to 12 months for detecting cracked or deformed members, worn or distorted parts such as pins, bearings and shafts as well as excessive wear on brakes: (a) Worksite: On or about 3/20/2018, the employer did not ensure that a periodic inspection of all overhead cranes was conducted. |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19100184 C01 |
Issuance Date |
2018-03-23 |
Abatement Due Date |
2018-05-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-04-10 |
Nr Instances |
6 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.184(c)(1): Slings that were damaged or defective were used: (a) Worksite: On or about 3/20/2018, the employer did not take damaged (worn and torn) web slings out of service. |
|
Citation ID |
01001C |
Citaton Type |
Other |
Standard Cited |
19100184 C14 |
Issuance Date |
2018-03-23 |
Abatement Due Date |
2018-05-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-04-10 |
Nr Instances |
9 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.184(c)(14): Slings were used without having affixed and legible identification markings: (a) Worksite: On or about 3/20/2018, the employer did not take web slings with missing or illegible data tags out of service. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2018-03-23 |
Abatement Due Date |
2018-05-22 |
Current Penalty |
2200.0 |
Initial Penalty |
3141.0 |
Final Order |
2018-04-10 |
Nr Instances |
3 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Worksite: (1) On or about 3/20/2018, the employer did not ensure that lathe chuck guards were installed for use on lathes such as, but not limited to: Warner & Swasey No. 5, Reed-Prentice and the Clausing Lathe. (2) On or about 3/20/2018, the employer did not ensure that the drive wheels on the two Marvel Band Saws in the welding area were guarded below the cutting table. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100212 B |
Issuance Date |
2018-03-23 |
Abatement Due Date |
2018-05-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-04-10 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(b): Machines designed for fixed locations were not securely anchored to prevent walking or moving: (a) Worksite: Machine Shop and Welding Department: On or about 3/20/2018, the employer did not ensure that the Dayton pedestal grinder and the Buffalo FDM-12 drill press were secured from walking and movement. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
2018-03-23 |
Abatement Due Date |
2018-05-22 |
Current Penalty |
0.0 |
Initial Penalty |
2513.0 |
Final Order |
2018-04-10 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: (a) Workplace - Welding Department: On or about 3/20/2018, the employer did not ensure that the Ryobi six inch grinder was used with its tool work rests, leaving a gap of approximately one-half inch to the grinding wheel. |
|
Citation ID |
01002D |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2018-03-23 |
Abatement Due Date |
2018-05-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-04-10 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch: (a) Worksite: Machine Shop and the Welding Department: On or about 3/20/2018, the employer did not ensure that the tongue guards were in place on the Ryobi six inch grinder and the General Electric grinder, leaving a gap of approximately one-half inch on the Ryobi and more than two inches on the General Electric model. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100147 C04 II |
Issuance Date |
2018-03-23 |
Abatement Due Date |
2018-05-22 |
Current Penalty |
0.0 |
Initial Penalty |
353.0 |
Final Order |
2018-04-10 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): (a) Worksite: On or about 3/20/2018, the employer had not developed written machine specific Lockout/Tag-out procedures for the control of hazardous energy. |
|
Citation ID |
02002A |
Citaton Type |
Other |
Standard Cited |
19100178 A06 |
Issuance Date |
2018-03-23 |
Abatement Due Date |
2018-05-22 |
Current Penalty |
0.0 |
Initial Penalty |
353.0 |
Final Order |
2018-04-10 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates and markings were in place: (a) Worksite: On or about 3/20/2018, the employer did not ensure that the Komatsu FG25 forklift had a data plate. |
|
Citation ID |
02002B |
Citaton Type |
Other |
Standard Cited |
19100178 L04 III |
Issuance Date |
2018-03-23 |
Abatement Due Date |
2018-05-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-04-10 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: (a) Worksite: On or about 3/20/2018, the employer did not ensure that each forklift operator received a forklift skills evaluation once every three years. |
|
|
300091808
|
0112300
|
1997-01-15
|
225 HOPKINS HILL ROAD, COVENTRY, RI, 02816
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
1997-01-15
|
Case Closed |
2011-01-05
|
|
122516271
|
0112300
|
1994-11-10
|
225 HOPKINS HILL ROAD, COVENTRY, RI, 02816
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
1994-11-10
|
Case Closed |
1994-12-15
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100038 A01 |
Issuance Date |
1994-11-18 |
Abatement Due Date |
1995-05-10 |
Nr Instances |
1 |
Nr Exposed |
25 |
Gravity |
00 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100038 B01 |
Issuance Date |
1994-11-18 |
Abatement Due Date |
1995-05-10 |
Nr Instances |
1 |
Nr Exposed |
25 |
Gravity |
00 |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19100304 F05 V |
Issuance Date |
1994-11-18 |
Abatement Due Date |
1994-11-23 |
Nr Instances |
1 |
Nr Exposed |
20 |
Gravity |
00 |
|
Citation ID |
01004 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
1994-11-18 |
Abatement Due Date |
1995-05-10 |
Nr Instances |
1 |
Nr Exposed |
25 |
Gravity |
00 |
|
|