Search icon

Daniele International, Inc.

Headquarter

Company Details

Name: Daniele International, Inc.
Jurisdiction: Rhode Island
Entity type: Domestic Profit Corporation
Status: Conversion
Date of Organization in Rhode Island: 24 Oct 1975 (49 years ago)
Date of Dissolution: 15 Apr 2020 (5 years ago)
Date of Status Change: 15 Apr 2020 (5 years ago)
Identification Number: 000006056
ZIP code: 02859
County: Providence County
Principal Address: 105 DAVIS DRIVE P.O. BOX 106, PASCOAG, RI, 02859, USA
Purpose: ITALIAN GOURMET FOOD
Fictitious names: DANIELE, INC. (trading name, 2004-12-02 - )
Historical names: DANIELE PROSCIUTTO, INC.

Industry & Business Activity

NAICS

311612 Meat Processed from Carcasses

This U.S. industry comprises establishments primarily engaged in processing or preserving meat and meat byproducts (except poultry and small game) from purchased meats. This industry includes establishments primarily engaged in assembly cutting and packing of meats (i.e., boxed meats) from purchased meats. Learn more at the U.S. Census Bureau

Links between entities

Type Company Name Company Number State
Headquarter of Daniele International, Inc., CONNECTICUT 0804418 CONNECTICUT

SECRETARY

Name Role Address
RYAN SCHWEET SECRETARY 105 DAVIS DRIVE, P.O. BOX 106 PASCOAG, RI 02859 USA

PRESIDENT

Name Role Address
STEFANO DUKCEVICH PRESIDENT 105 DAVIS DRIVE, PO BOX 106 PASCOAG, RI 02859-0106 USA

VICE PRESIDENT

Name Role Address
RYAN SCHWEET VICE PRESIDENT 105 DAVIS DRIVE, PO BOX 106 PASCOAG, RI 02859 USA

Agent

Name Role Address
HASLAW, INC. Agent 100 WESTMINSTER STREET SUITE 1500 C/O HINCKLEY ALLEN, PROVIDENCE, RI, 02903, USA

DIRECTOR

Name Role Address
RYAN SCHWEET DIRECTOR 105 DAVIS DRIVE, P.O. BOX 106 PASCOAG, RI 02859 USA

Events

Type Date Old Value New Value
Name Change 2001-12-27 DANIELE PROSCIUTTO, INC. Daniele International, Inc.
Merged 2001-12-27 Gio Internation Daniele International, Inc.

Filings

Number Name File Date
202037611910 Certificate of Conversion 2020-04-15
202037478180 Annual Report 2020-04-13
201918546950 Statement of Change of Registered/Resident Agent 2019-09-09
201984442750 Annual Report 2019-01-15
201856179050 Annual Report 2018-01-16
201734483390 Annual Report 2017-02-22
201691259900 Annual Report 2016-01-26
201554629550 Annual Report 2015-02-05
201448688340 Statement of Change of Registered/Resident Agent 2014-10-22
201432556800 Annual Report 2014-01-08

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345080295 0112300 2020-12-29 1000 DANIELE DRIVE, MAPLEVILLE, RI, 02839
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2020-12-29
Case Closed 2021-07-28

Related Activity

Type Referral
Activity Nr 1712437
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2021-06-15
Abatement Due Date 2021-07-30
Current Penalty 7509.6
Initial Penalty 10728.0
Final Order 2021-06-29
Nr Instances 1
Nr Exposed 50
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) At the facility: On or about 12/28/2020, employees were exposed to a hazardous chemical (Quat Powdered Floor Cleaner) and were not provided effective information and training on the handling and use of this chemical product.
344163860 0112300 2019-07-17 105 DAVIS DRIVE, PASCOAG, RI, 02859
Inspection Type Planned
Scope Partial
Safety/Health Health
Close Conference 2019-07-17
Emphasis L: R1Noise, P: R1Noise
Case Closed 2020-01-22

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100095 D01
Issuance Date 2019-12-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-01-21
Nr Instances 1
Nr Exposed 300
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceeded the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program: (a) Food Production Areas: On or about 7-17-19, when information indicated that any employee's exposure equaled or exceeded the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a noise monitoring program.
343560496 0112300 2018-10-26 1000 DANIELE DRIVE, MAPLEVILLE, RI, 02839
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2018-10-26
Emphasis N: AMPUTATE
Case Closed 2019-01-15

Related Activity

Type Referral
Activity Nr 1394641
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100147 C04 I
Issuance Date 2018-12-10
Abatement Due Date 2018-12-19
Current Penalty 10000.0
Initial Penalty 12934.0
Contest Date 2018-12-31
Final Order 2019-01-08
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Worksite: On or about 10/23/2018, the employer did not ensure that the Lockout-Tag/out procedure developed for the Intralox Conveyor System was utilized by employees performing sanitation activities on this equipment.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100147 C06 II
Issuance Date 2018-12-10
Abatement Due Date 2019-01-28
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2018-12-31
Final Order 2019-01-08
Nr Instances 1
Nr Exposed 8
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: (a) Worksite: On or about 10/26/2018, the employer did not ensure that periodic inspections of Lockout/Tag-out energy control procedures took place.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100147 C07 I B
Issuance Date 2018-12-10
Abatement Due Date 2019-01-28
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2018-12-31
Final Order 2019-01-08
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: (a) Worksite: On or about 10/23/2018, the employer did not ensure that each employee affected by Lockout/Tag-out was properly trained in the energy control procedure.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19100147 C07 IV
Issuance Date 2018-12-10
Abatement Due Date 2019-01-28
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2018-12-31
Final Order 2019-01-08
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date: (a) Worksite: On or about 10/26/2018, the employer had not certified that employee training occurred for each employee requiring it.
342761665 0112300 2017-11-08 1000 DANIELE DRIVE, MAPLEVILLE, RI, 02839
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2017-11-08
Emphasis L: EISAOF, L: EISAX30, L: FORKLIFT, N: AMPUTATE, P: AMPUTATE
Case Closed 2017-11-30

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2017-11-15
Abatement Due Date 2018-01-03
Current Penalty 5576.0
Initial Penalty 7967.0
Final Order 2017-11-30
Nr Instances 7
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to collapse and struck-by hazards caused by damaged pallet rack systems: (a) Snack Pack Warehouse: On or about 11/8/2017, the employer did not ensure that damaged pallet rack uprights were taken out of service before material was stored on racking cross members.
340154855 0112300 2014-11-18 1000 DANIELE DRIVE, BURRILLVILLE, RI, 02830
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2015-05-04
Emphasis L: FALL
Case Closed 2015-06-03

Related Activity

Type Complaint
Activity Nr 921171
Safety Yes
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2015-05-04
Abatement Due Date 2015-10-27
Current Penalty 1912.0
Initial Penalty 3825.0
Final Order 2015-05-27
Nr Instances 2
Nr Exposed 6
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Meat Grinding Area: Employees, using a step stool to monitor the meat processing within the vat, were exposed to the rotating auger blades, rotating mixing paddles and rotating grinder within the open surface meat vat of the Velati meat grinding equipment. b) Meat Grinding Area: Employees, using a step stool to monitor the meat processing within the vat, were exposed to falling onto the takeout rotating conveyor belt of the Velati meat grinding equipment.
340056225 0112300 2014-10-30 105 DAVIS DRIVE, PASCOAG, RI, 02859
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2014-12-11
Emphasis L: EISAX50, L: EISAOF
Case Closed 2015-03-10

Related Activity

Type Complaint
Activity Nr 916480
Safety Yes
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100132 A
Issuance Date 2014-12-16
Abatement Due Date 2015-01-12
Current Penalty 2750.0
Initial Penalty 5500.0
Final Order 2015-01-20
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided and used wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact: (a) Facility: Personal protective equipment, such as waterproof insulating gloves, was not provided for employees working with hot water, with temperatures up to 180 degrees Fahrenheit, on or about 10-30-14.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100132 D01
Issuance Date 2014-12-16
Abatement Due Date 2015-01-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-01-20
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): (a) Facility: The employer did not perform an adequate hazard assessment of operations involving the use of hot water to determine the proper equipment to be used for this task, on or about 10-30-14.
339437998 0112300 2013-10-23 105 DAVIS DR, PASCOAG, RI, 02859
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2013-11-12
Emphasis L: FORKLIFT
Case Closed 2014-01-28

Related Activity

Type Complaint
Activity Nr 856851
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 C04 I
Issuance Date 2013-12-04
Abatement Due Date 2014-01-28
Current Penalty 3500.0
Initial Penalty 7000.0
Final Order 2014-01-08
Nr Instances 1
Nr Exposed 26
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Facilities 105 Davis Dr, 180 Davis Dr and 1000 Daniele Dr: Energy control procedures were not utilized during the daily cleaning and sanitation of machinery and equipment at the facilities, on or about 10-23-13.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100147 C04 II B
Issuance Date 2013-12-04
Abatement Due Date 2014-01-28
Current Penalty 3500.0
Initial Penalty 7000.0
Final Order 2014-01-08
Nr Instances 1
Nr Exposed 26
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: (a) 105 Davis Dr: The energy control procedure for the Gouging Machine did not clearly and specifically outline the steps for shutting down the machine in that the procedure contained step number 2 for the shutting down of a valve that was no longer present on the machine, on or about 10-29-13. (b) 105 Davis Dr: The energy control procedure for the Dip Tank did not clearly and specifically outline the steps for shutting down the machine in that the procedure contained step number 1 for the shutting down of a valve that was no longer present on the machine, on or about 10-29-13. (c) 180 Davis Dr: The energy control procedures for the Multivac and Multivac Heat Shrink Tunnel did not clearly and specifically outline the steps for shutting down the machine in that the procedures did not identify any specific energy isolating devices to be used or their locations or procedures for operation of these devices, on or about 10-29-13.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100147 C04 II D
Issuance Date 2013-12-04
Abatement Due Date 2014-01-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-01-08
Nr Instances 1
Nr Exposed 26
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control: (a) 105 Davis Dr: The energy control procedure for the Gouging Machine did not clearly and specifically outline the requirements for testing the machine to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control, on or about 10-29-13. (b) 105 Davis Dr: The energy control procedure for the Dip Tank did not clearly and specifically outline the requirements for testing the machine to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control, on or about 10-29-13. (c) 180 Davis Dr: The energy control procedures for the Multivac and Multivac Heat Shrink Tunnel did not clearly and specifically outline the requirements for testing the machine to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control, on or about 10-29-13.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100147 C06 I
Issuance Date 2013-12-04
Abatement Due Date 2014-01-28
Current Penalty 3500.0
Initial Penalty 7000.0
Final Order 2014-01-08
Nr Instances 1
Nr Exposed 26
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) Facilities 105 Davis Dr, 180 Davis Dr and 1000 Daniele Dr: The employer did not conduct a periodic inspection of the energy control procedures used throughout the facilities at least annually, on or about 10-23-13.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19100147 C07 I A
Issuance Date 2013-12-04
Abatement Due Date 2014-01-28
Current Penalty 3500.0
Initial Penalty 7000.0
Final Order 2014-01-08
Nr Instances 1
Nr Exposed 26
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: (a) Facilities 105 Davis Dr, 180 Davis Dr and 1000 Daniele Dr: The employer did not train any authorized employees in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control as part of the sanitation process throughout the facilities, on or about 10-23-13.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19100147 C07 I B
Issuance Date 2013-12-04
Abatement Due Date 2014-01-28
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-01-08
Nr Instances 1
Nr Exposed 26
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: (a) Facilities 105 Davis Dr, 180 Davis Dr and 1000 Daniele Dr: The employer did not instruct affected employees, such as but not limited to sanitation workers throughout the facilities, in the purpose and use of the energy control procedures, on or about 10-23-13.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100178 L01 II
Issuance Date 2013-12-04
Current Penalty 2000.0
Initial Penalty 4000.0
Final Order 2014-01-08
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck: (a) Facilities 105 Davis Dr, 180 Davis Dr and 1000 Daniele Dr: The employer permitted employees to operate powered industrial trucks used throughout the facilities before successfully completing the training required by paragraph l, on or about 10-23-13.
Citation ID 02001
Citaton Type Other
Standard Cited 19100132 D02
Issuance Date 2013-12-04
Abatement Due Date 2014-03-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-01-08
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2): (a) Facilities 105 Davis Dr, 180 Davis Dr and 1000 Daniele Dr: A written certification of the workplace hazard assessment for Personal Protective Equipment for employees working in the facility was not available on or about 10-23-13.
310157938 0112300 2007-09-06 1000 DANIELE DRIVE, MAPLEVILLE, RI, 02839
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2008-02-28
Emphasis S: AMPUTATIONS, N: AMPUTATE
Case Closed 2008-10-01

Related Activity

Type Referral
Activity Nr 200765022
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2008-03-05
Abatement Due Date 2008-03-10
Current Penalty 4000.0
Initial Penalty 4000.0
Nr Instances 1
Gravity 10
Hazard CUTS
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100147 C04 II
Issuance Date 2008-03-05
Abatement Due Date 2008-09-30
Current Penalty 4000.0
Initial Penalty 4000.0
Nr Instances 1
Gravity 10
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100147 C06 I
Issuance Date 2008-03-05
Abatement Due Date 2008-09-30
Nr Instances 1
Gravity 02
307578369 0112300 2006-08-18 105 DAVIS DRIVE, PASCOAG, RI, 02859
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2006-11-13
Emphasis N: AMPUTATE
Case Closed 2007-01-05

Related Activity

Type Referral
Activity Nr 200763571
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2006-11-28
Abatement Due Date 2007-01-03
Current Penalty 1500.0
Initial Penalty 2500.0
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Accident
Gravity 10
Citation ID 02001
Citaton Type Other
Standard Cited 19040002 A
Issuance Date 2006-11-28
Abatement Due Date 2007-01-17
Nr Instances 2
Gravity 00
304991052 0112300 2003-02-12 105 DAVIS DRIVE, PASCOAG, RI, 02859
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2003-02-14
Emphasis S: FOOD PROCESSING, N: AMPUTATE
Case Closed 2003-06-13

Related Activity

Type Referral
Activity Nr 200099158
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2003-03-20
Abatement Due Date 2003-03-25
Current Penalty 1000.0
Initial Penalty 1000.0
Nr Instances 1
Nr Exposed 20
Related Event Code (REC) Referral
Gravity 10
Citation ID 02001
Citaton Type Other
Standard Cited 19040032 B02
Issuance Date 2003-03-20
Abatement Due Date 2003-04-15
Nr Instances 1
Gravity 00
Citation ID 02002
Citaton Type Other
Standard Cited 19040032 B03
Issuance Date 2003-03-20
Abatement Due Date 2003-04-15
Nr Instances 1
Gravity 00
Citation ID 02003
Citaton Type Other
Standard Cited 19040032 B06
Issuance Date 2003-03-20
Abatement Due Date 2003-04-15
Nr Instances 1
Gravity 00
Inspection Type Planned
Scope Complete
Safety/Health Health
Close Conference 1998-07-24
Emphasis N: GSINTARG
Case Closed 1998-09-23

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100133 A01
Issuance Date 1998-08-14
Abatement Due Date 1998-10-01
Nr Instances 1
Nr Exposed 8
Gravity 01
Citation ID 01002
Citaton Type Other
Standard Cited 19101200 E01 I
Issuance Date 1998-08-14
Abatement Due Date 1998-10-01
Nr Instances 4
Nr Exposed 80
Gravity 01
Citation ID 01003
Citaton Type Other
Standard Cited 19101200 G08
Issuance Date 1998-08-14
Abatement Due Date 1998-09-10
Nr Instances 1
Nr Exposed 3
Gravity 01
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 1998-06-17
Case Closed 1998-12-01

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100036 B05
Issuance Date 1998-06-18
Abatement Due Date 1998-07-15
Current Penalty 437.5
Initial Penalty 875.0
Nr Instances 5
Nr Exposed 11
Gravity 02
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100036 D01
Issuance Date 1998-06-18
Abatement Due Date 1998-07-15
Nr Instances 2
Nr Exposed 11
Gravity 02
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100037 Q01
Issuance Date 1998-06-18
Abatement Due Date 1998-07-15
Nr Instances 2
Nr Exposed 11
Gravity 02
Citation ID 01001D
Citaton Type Serious
Standard Cited 19100038 A01
Issuance Date 1998-06-18
Abatement Due Date 1998-08-05
Nr Instances 1
Nr Exposed 11
Gravity 02
Citation ID 01001E
Citaton Type Serious
Standard Cited 19100038 A05 II
Issuance Date 1998-06-18
Abatement Due Date 1998-08-05
Nr Instances 1
Nr Exposed 11
Gravity 02
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100101 B
Issuance Date 1998-06-18
Abatement Due Date 1998-07-15
Current Penalty 350.0
Initial Penalty 700.0
Nr Instances 5
Nr Exposed 1
Gravity 02
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100253 B02 IV
Issuance Date 1998-06-18
Abatement Due Date 1998-07-15
Nr Instances 2
Nr Exposed 1
Gravity 02
Citation ID 01002C
Citaton Type Serious
Standard Cited 19100254 D09 I
Issuance Date 1998-06-18
Abatement Due Date 1998-07-15
Nr Instances 1
Nr Exposed 1
Gravity 02
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 1998-06-18
Abatement Due Date 1998-09-17
Current Penalty 437.5
Initial Penalty 875.0
Nr Instances 5
Nr Exposed 7
Gravity 03
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 1998-06-18
Abatement Due Date 1998-07-15
Nr Instances 1
Nr Exposed 1
Gravity 03
Citation ID 01004A
Citaton Type Serious
Standard Cited 19100303 B01
Issuance Date 1998-06-18
Abatement Due Date 1998-07-15
Current Penalty 1250.0
Initial Penalty 2500.0
Nr Instances 1
Nr Exposed 3
Gravity 10
Citation ID 01004B
Citaton Type Serious
Standard Cited 19100303 G02 I
Issuance Date 1998-07-02
Abatement Due Date 1998-07-29
Nr Instances 1
Nr Exposed 2
Gravity 10
Citation ID 01005
Citaton Type Serious
Standard Cited 19100305 J02 II
Issuance Date 1998-06-18
Abatement Due Date 1998-08-05
Current Penalty 1250.0
Initial Penalty 2500.0
Nr Instances 16
Nr Exposed 11
Gravity 10
Citation ID 01006A
Citaton Type Serious
Standard Cited 19100304 F04
Issuance Date 1998-06-18
Abatement Due Date 1998-07-15
Current Penalty 1250.0
Initial Penalty 2500.0
Nr Instances 1
Nr Exposed 2
Gravity 03
Citation ID 01006B
Citaton Type Serious
Standard Cited 19100305 A01 I
Issuance Date 1998-07-02
Abatement Due Date 1998-07-29
Nr Instances 1
Nr Exposed 2
Gravity 03
Citation ID 01006C
Citaton Type Serious
Standard Cited 19100305 B02
Issuance Date 1998-06-18
Abatement Due Date 1998-07-15
Nr Instances 3
Gravity 03
Citation ID 01006D
Citaton Type Serious
Standard Cited 19100305 G01 I
Issuance Date 1998-06-18
Abatement Due Date 1998-08-05
Nr Instances 3
Nr Exposed 3
Gravity 03
Citation ID 02001
Citaton Type Other
Standard Cited 19100022 A01
Issuance Date 1998-06-18
Abatement Due Date 1998-08-05
Nr Instances 1
Nr Exposed 1
Gravity 01
Citation ID 02002
Citaton Type Other
Standard Cited 19100022 A02
Issuance Date 1998-06-18
Abatement Due Date 1998-07-15
Current Penalty 175.0
Initial Penalty 350.0
Nr Instances 2
Nr Exposed 4
Gravity 03
Citation ID 02003
Citaton Type Other
Standard Cited 19100023 A08
Issuance Date 1998-06-18
Abatement Due Date 1998-07-15
Nr Instances 2
Nr Exposed 2
Gravity 01
Citation ID 02004
Citaton Type Other
Standard Cited 19100141 G02
Issuance Date 1998-06-18
Abatement Due Date 1998-07-15
Nr Instances 2
Nr Exposed 1
Gravity 01
Citation ID 02005
Citaton Type Other
Standard Cited 19100147 C04 I
Issuance Date 1998-06-18
Abatement Due Date 1998-08-05
Nr Instances 1
Nr Exposed 11
Gravity 01
Citation ID 02006
Citaton Type Other
Standard Cited 19100147 C07 I
Issuance Date 1998-06-18
Abatement Due Date 1998-08-05
Nr Instances 1
Nr Exposed 7
Gravity 01
Citation ID 02007
Citaton Type Other
Standard Cited 19100157 C01
Issuance Date 1998-06-18
Abatement Due Date 1998-07-15
Nr Instances 1
Nr Exposed 1
Gravity 01
Citation ID 02008
Citaton Type Other
Standard Cited 19100178 M05 I
Issuance Date 1998-06-18
Abatement Due Date 1998-07-15
Nr Instances 1
Nr Exposed 2
Gravity 01
Citation ID 02009
Citaton Type Other
Standard Cited 19100303 E
Issuance Date 1998-06-18
Abatement Due Date 1998-07-15
Nr Instances 3
Nr Exposed 2
Gravity 01
Citation ID 02010
Citaton Type Other
Standard Cited 19100303 G01 II
Issuance Date 1998-06-18
Abatement Due Date 1998-07-15
Nr Instances 3
Nr Exposed 3
Gravity 01
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 1991-02-26
Case Closed 1991-04-02

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100215 A04
Issuance Date 1991-03-05
Abatement Due Date 1991-03-11
Current Penalty 200.0
Initial Penalty 200.0
Nr Instances 1
Nr Exposed 1
Gravity 05
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100215 B09
Issuance Date 1991-03-05
Abatement Due Date 1991-03-22
Nr Instances 1
Nr Exposed 1
Gravity 05
Citation ID 02001
Citaton Type Other
Standard Cited 19030002 A01
Issuance Date 1991-03-05
Abatement Due Date 1991-03-08
Current Penalty 40.0
Initial Penalty 40.0
Nr Instances 1
Nr Exposed 40
Gravity 00
Citation ID 02002
Citaton Type Other
Standard Cited 19040002 A
Issuance Date 1991-03-05
Abatement Due Date 1991-03-12
Current Penalty 40.0
Initial Penalty 40.0
Nr Instances 1
Nr Exposed 40
Gravity 00
Citation ID 02003
Citaton Type Other
Standard Cited 19100147 C04 I
Issuance Date 1991-03-05
Abatement Due Date 1991-04-05
Nr Instances 1
Nr Exposed 40
Gravity 03
Citation ID 02004
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 1991-03-05
Abatement Due Date 1991-04-05
Nr Instances 1
Nr Exposed 40
Gravity 03
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 1986-02-06
Case Closed 1986-03-21

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100178 M03
Issuance Date 1986-02-21
Abatement Due Date 1986-03-21
Current Penalty 60.0
Initial Penalty 120.0
Nr Instances 1
Nr Exposed 1
Citation ID 01002
Citaton Type Serious
Standard Cited 19100219 E01 I
Issuance Date 1986-02-21
Abatement Due Date 1986-03-21
Current Penalty 60.0
Initial Penalty 120.0
Nr Instances 1
Nr Exposed 1
Citation ID 01003
Citaton Type Serious
Standard Cited 19100303 G02 I
Issuance Date 1986-02-21
Abatement Due Date 1986-02-26
Current Penalty 100.0
Initial Penalty 200.0
Nr Instances 1
Nr Exposed 1
Citation ID 02001
Citaton Type Other
Standard Cited 19100037 K02
Issuance Date 1986-02-21
Abatement Due Date 1986-02-26
Nr Instances 1
Nr Exposed 4
Citation ID 02002
Citaton Type Other
Standard Cited 19100101 B
Issuance Date 1986-02-21
Abatement Due Date 1986-02-26
Nr Instances 2
Nr Exposed 1
Citation ID 02003
Citaton Type Other
Standard Cited 19100215 A04
Issuance Date 1986-02-26
Abatement Due Date 1986-02-26
Nr Instances 1
Nr Exposed 1
Citation ID 02004
Citaton Type Other
Standard Cited 19100252 A02 IIB
Issuance Date 1986-02-21
Abatement Due Date 1986-02-26
Nr Instances 3
Nr Exposed 2
Citation ID 02005
Citaton Type Other
Standard Cited 19100252 A02 IVE
Issuance Date 1986-02-21
Abatement Due Date 1986-02-26
Nr Instances 3
Nr Exposed 2
Citation ID 02006
Citaton Type Other
Standard Cited 19100305 B01
Issuance Date 1986-02-21
Abatement Due Date 1986-02-26
Nr Instances 1
Nr Exposed 4
Citation ID 02007
Citaton Type Other
Standard Cited 19100305 B02
Issuance Date 1986-02-21
Abatement Due Date 1986-02-26
Nr Instances 2
Nr Exposed 1
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 1982-12-30
Case Closed 1983-02-03

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100178 M03
Issuance Date 1983-01-06
Abatement Due Date 1983-01-09
Nr Instances 1

Date of last update: 06 Apr 2025