346627250
|
0112300
|
2023-04-12
|
444 CENTRAL STREET, CENTRAL FALLS, RI, 02863
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2023-04-12
|
Emphasis |
L: FORKLIFT, P: AMPUTATE, N: AMPUTATE
|
Case Closed |
2023-11-27
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100134 E01 |
Issuance Date |
2023-07-26 |
Abatement Due Date |
2023-09-11 |
Current Penalty |
3643.2 |
Initial Penalty |
4554.0 |
Final Order |
2023-09-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace. a) Paint booth: On or about 4/12/2023, the employer did not provide a medical evaluation to determine each employee's ability to use a respirator prior to requiring use. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100134 F02 |
Issuance Date |
2023-07-26 |
Abatement Due Date |
2023-09-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-09-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator. a) Jobsite: On or about 4/12/2023, the employer did not provide a fit-test to all employees required to wear respirators. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100134 G01 I A |
Issuance Date |
2023-07-26 |
Abatement Due Date |
2023-08-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-09-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function. a) Jobsite: On or about 4/12/2023, the employer allowed an EE with facial hair to wear a respirator that interfered with the seal. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2023-07-26 |
Abatement Due Date |
2023-09-11 |
Current Penalty |
0.0 |
Initial Penalty |
4554.0 |
Final Order |
2023-09-11 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. a) The Shop: On or about 4/12/2023, employees operating the Hem Saw were exposed to an unguarded band saw blade. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100215 A01 |
Issuance Date |
2023-07-26 |
Abatement Due Date |
2023-09-11 |
Current Penalty |
3036.0 |
Initial Penalty |
3795.0 |
Final Order |
2023-09-11 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(1): Abrasive wheel(s) used on grinding machinery were not used with safety guard(s). a) The Shop: On or about 4/12/2023, the employer did not ensure a Rotary Surface Grinder was equipped with a safety guard. b) The Shop: On or about 4/12/2023, the employer did not ensure a Dayton Bench Grinder was equipped with a safety guard. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100134 K06 |
Issuance Date |
2023-07-26 |
Abatement Due Date |
2023-09-11 |
Current Penalty |
340.8 |
Initial Penalty |
426.0 |
Final Order |
2023-09-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer. a) Jobsite: On or about 4/12/2023, the employer did not provide Appendix D to employees in a language that they understood. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100178 A05 |
Issuance Date |
2023-07-26 |
Abatement Due Date |
2023-09-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-09-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered. a) The Shop: On or about 4/12/2023, the employer did not ensure a powered industrial truck with a Hercules Boom was marked to include the attachment modifications. |
|
|
341300044
|
0112300
|
2016-03-03
|
444 CENTRAL STREET, CENTRAL FALLS, RI, 02863
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-03-03
|
Emphasis |
L: FORKLIFT, P: AMPUTATE, N: AMPUTATE
|
Case Closed |
2016-09-08
|
Related Activity
Type |
Referral |
Activity Nr |
1068412 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2016-08-09 |
Abatement Due Date |
2016-09-01 |
Current Penalty |
2543.0 |
Initial Penalty |
3634.0 |
Final Order |
2016-08-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts and flying chips: (a) Hammer Department: On or about March 3, 2016, adequate guarding was not provided for the point of operation and rotating parts of the lathe when an employee was performing hammer head tapping. |
|
|
122516099
|
0112300
|
1994-10-27
|
444 CENTRAL STREET, CENTRAL FALLS, RI, 02863
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
1994-11-01
|
Case Closed |
1995-08-29
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100095 C01 |
Issuance Date |
1994-11-16 |
Abatement Due Date |
1995-08-15 |
Current Penalty |
262.5 |
Initial Penalty |
525.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
05 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100095 D01 |
Issuance Date |
1994-11-16 |
Abatement Due Date |
1995-05-08 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
02 |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100095 I02 I |
Issuance Date |
1994-11-16 |
Abatement Due Date |
1995-05-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
02 |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100107 B03 |
Issuance Date |
1994-11-16 |
Abatement Due Date |
1994-11-21 |
Current Penalty |
750.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100107 B05 I |
Issuance Date |
1994-11-16 |
Abatement Due Date |
1994-11-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19100107 B05 IV |
Issuance Date |
1994-11-16 |
Abatement Due Date |
1995-01-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01002D |
Citaton Type |
Serious |
Standard Cited |
19100107 B08 |
Issuance Date |
1994-11-16 |
Abatement Due Date |
1994-11-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01002E |
Citaton Type |
Serious |
Standard Cited |
19100107 C02 |
Issuance Date |
1994-11-16 |
Abatement Due Date |
1994-12-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01002F |
Citaton Type |
Serious |
Standard Cited |
19100107 E09 |
Issuance Date |
1994-11-16 |
Abatement Due Date |
1994-11-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100108 C01 |
Issuance Date |
1994-11-16 |
Abatement Due Date |
1995-05-08 |
Current Penalty |
262.5 |
Initial Penalty |
525.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
05 |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100108 E02 |
Issuance Date |
1994-11-16 |
Abatement Due Date |
1995-05-08 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
02 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
1994-11-16 |
Abatement Due Date |
1994-11-21 |
Current Penalty |
150.0 |
Initial Penalty |
300.0 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
02 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100215 A02 |
Issuance Date |
1994-11-16 |
Abatement Due Date |
1994-11-21 |
Current Penalty |
150.0 |
Initial Penalty |
300.0 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
02 |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100219 C02 I |
Issuance Date |
1994-11-16 |
Abatement Due Date |
1994-11-21 |
Current Penalty |
150.0 |
Initial Penalty |
300.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
02 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100134 B01 |
Issuance Date |
1994-11-16 |
Abatement Due Date |
1995-08-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
00 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100134 B08 |
Issuance Date |
1994-11-16 |
Abatement Due Date |
1995-08-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
00 |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
1994-11-16 |
Abatement Due Date |
1995-05-08 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
00 |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19101200 F05 I |
Issuance Date |
1994-11-16 |
Abatement Due Date |
1994-11-21 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
00 |
|
|